QQ

3165088973

电话

15685359870

WhatsApp

+86 15685359870

IS200DSFCG1ACA Turbine Control

TheIS200DSFCG1ACAmodelispartoftheMarkVIIS200seriesfromGeneralElectric.Thismodelw
Send Inquiry
Description
Argument
Products Description
The IS200DSFCG1ACA model is part of the Mark VI IS200 series from General Electric. This model was designed as a 1000/1800 Amp Gate Driver/Shunt Feedback Board. This model is a revision of the G1 group, which is used in source applications where the AC input is 600 V LL rms.



All published products are in stock, and images cannot correspond to each one. We have inventory and can contact professional customer service personnel

Phone 15685359870

mailbox3165088973@qq.com



VMIVME-7807RC.刘燕华.20210323_175249 (2).jpg



Frequently Asked Questions about IS200DSFCG1ACA

What are the faults that can be detected by the driver circuits on the IS200DSFCG1ACA board?

Two fault types can be detected on the IS200DSFCG1ACA model through the driver circuits. The faults are a desaturation fault and an undervoltage fault. The faults will be reported through a multiplexed differential fault for both lower and upper IGBT circuits. The undervoltage fault will be indicated when the voltage between the +15 and -15 V supplies drops below 20 V. The desaturation fault on the IS200DSFCG1ACA model will be indicated when the gate driver is commanded to turn the IGBT on, and the voltage drop between the collector and emitter of the IGBT is monitored; when the voltage exceeds 10 V for longer than four microseconds a desaturation fault will be called. When the desaturation fault has occurred on the DSFC model the BPIB board will operate the DSFC board in burst mode, where a PWM signal of 2 MHz is used to slowly decrease the gate voltage to zero. 



微信图片_20220402160532.png



Product Introduction

Main products, advantageous supply, and sufficient inventory

The ABB PLC system module DCS system card includes some discontinued control system module cards. (For example: PM645B, 5SHY3545L0014, PM630, 07AC91D, SPHSS13PP845PFEA111-20PFEA112-65 PPD113B01-10-150000, PPD115A102PPD113-B03-23-111615)

◆ GE gas turbine cards: IS200 series, DS200 series, etc. (such as IS200TRPGH1B, DS200PCCAG1A) ◆ Triconex: redundant fault-tolerant control system, modern fault-tolerant controller based on Triple Modular Redundancy (TMR) structure. (For example: 3721, 3625, 3008, 4351B, 3805E)

Foxboro: 1/ASeries system, FBM (Field Input/Output Module) sequential control, etc. (e.g. FBM201CP270CP4BFCP280FCP270)

Bently Nevada: A card for a 3500 system. (e.g. 35/15350/2M5) HIMA (Black Horse): F8650X, F8627X, F8651X, F8652X, F35, etc

Motorola: MVME162, MVME167, MVME1772, MVME177 and other series XOOL: 1/0, Vne board and processor. (For example: XVME-653, XVME-674, XVME-976)

Rockvell (Allen Bradley): 1756, 1757, 1753, 1394 series. (For example: 1756-L73XT1756-L611757-SRM)

◆ Reliance: discontinued spare parts (e.g. 0-60002-6, 5-D4022, S-D4006-D)

Westinghouse Emerson: VE3007CE3008, 5X00105G145X00119G01, 1X00416H011X00416H01

Schneider: 14

 

 

 


Tags:

Technical parameter
公司营业执照及主营产品

公司营业执照及主营产品

Leave Your Message

标签form报错:该表单下没有新增表单属性。
Leave a message
标签form报错:该表单下没有新增表单属性。