GE 20836416 Control Frame Connection Module

GE 20836416 is control frame connection module for GE DCS, backplane bus router for interconnection of CPU, I/O and communication cards inside rack.
Send Inquiry
Description
Argument
Products Description
GE 20836416 | Control Frame Connection Module

GE 20836416 Control Frame Connection Module


GE 20836416是GE DCS系统控制框架连接模块,属于背板总线信号路由组件,负责机架内部CPU、I/O、通讯卡件之间的信号互联与中转。

GE 20836416 is control frame connection module for GE DCS, backplane bus router for interconnection of CPU, I/O and communication cards inside rack.

20836416  (4).jpeg

支持冗余通道快速切换,具备信号隔离与反接、过流保护,24VDC供电,用于电站、石化存量GE控制系统,属于停产工控备件。

Supports redundant channel switchover, signal isolation, reverse and overcurrent protection, 24VDC supply. Obsolete spare for legacy GE control systems.

20836416  (2).jpeg


Main Specifications 技术参数

  • 1. Product Series / 产品系列:GE DCS Control System

  • 2. Part Number / 型号:20836416

  • 3. Function / 功能:Backplane bus frame connection & signal routing

  • 4. Power Supply / 供电:24VDC, ±15% tolerance

  • 5. Protection / 保护:Overcurrent protection, reverse polarity protection

  • 6. Feature / 特性:Redundant signal switching, isolated transmission


Core Functions 核心功能

  • 1. 背板总线信号路由,实现机架内控制器、I/O卡件、通讯模块之间的数据交互。
    Backplane signal routing, realize data exchange between controller, I/O and communication modules in rack.

  • 2. 冗余信号链路切换,主链路故障时自动切换备用通道,保障控制信号不间断传输。
    Redundant signal link switching, automatic backup channel switch to keep control signal continuous.

  • 3. 信号隔离防护,隔离电压抑制现场干扰,降低浪涌、共模干扰对主控卡件的冲击。
    Signal isolation protection, suppress EMI and common-mode interference from field side.

  • 4. 内置电气保护,过流、电源反接保护,降低背板故障造成整套机架损坏风险。
    Built-in electrical protection against overcurrent and reverse power connection to protect rack hardware.

  • 5. 系统架构重组扩展,支持机架扩容、模块增减,适配项目技改时的框架调整需求。
    Support system reconstruction and expansion, adapt to rack modification during unit retrofit.


Application Scenarios 应用场景

  • 1. 火力发电厂、联合循环电站原有GE DCS控制柜机架通讯互联备件更换。
    Spare replacement for legacy GE DCS racks in thermal power and combined cycle power plants.

  • 2. 石化、化工装置GE分布式控制系统,背板链路故障后的恢复与维护。
    Maintenance and recovery for failed backplane links of GE DCS in petrochemical plants.

  • 3. 冶金、造纸行业存量GE工控机架技改扩容,实现框架重组与信号扩展。
    Rack reconstruction and signal expansion for GE control cabinets in metallurgy and paper industry.

  • 4. 海外成套工业控制项目配套GE DCS系统的框架连接备用备件。
    Frame connection spare parts for packaged GE DCS control systems for overseas projects.

  • 5. 电厂大修、控制系统隐患排查,替换老化背板连接组件,规避通讯中断风险。
    Replace aged backplane components during overhaul to avoid unexpected communication failure.


FAQ 常见问答

Q:20836416损坏会直接导致控制器跳闸吗?

A:该件为框架互联路由件,故障会造成机架内模块通讯中断,需要评估联锁逻辑,及时停机检修。

Q:不同批次的20836416能否直接互换?

A:硬件外形一致,更换前核对机架背板版本、固件版本,避免总线协议不匹配。


Similar Models 相似型号

GE IS200 Series Backplane Components

GE IS215VPROH2BC VPRO Board

GE IS230TRLSH1D Terminal Board

ABB S800 I/O Backplane Module

BENTLY 3500 Series Rack Backplane

EMERSON DeltaV Backplane Unit


Tags: GE GE 20836416 20836416 Control Frame Connection Module