ICS TRIPLEX 9100 T9100@F2 TMR Safety Processor Module

ICS TRIPLEX 9100 T9100@F2 is AADvance TMR safety processor with 3-2-0 fault tolerance, three independent channels run safety logic and perform hardware voting.
Send Inquiry
Description
Argument
Products Description
ICS TRIPLEX 9100 T9100@F2 | AADvance TMR Safety Processor Module

ICS TRIPLEX 9100 T9100@F2 TMR Safety Processor Module


ICS TRIPLEX 9100 T9100@F2是AADvance安全仪表系统核心TMR三重冗余处理器模块,采用3-2-0容错机制,三路独立运算通道同步执行安全逻辑并硬件表决。

ICS TRIPLEX 9100 T9100@F2 is AADvance TMR safety processor with 3-2-0 fault tolerance, three independent channels run safety logic and perform hardware voting.

9100 T9100@F2.jpeg

24VDC冗余供电,搭载双以太网与串口通讯,支持配套I/O模块热插拔,满足SIL3安全等级,用于ESD、火气系统、燃烧管理,产品已停产,作为石化电厂SIS控制柜备件流通。

Redundant 24VDC supply, dual Ethernet and serial ports, hot-swap I/O support, SIL3 certified. Obsolete, it is spare for SIS ESD and fire & gas cabinets.

9100 T9100@F2 (3).jpeg


Main Specifications 技术参数

  • 1. Product Series / 产品系列:ICS TRIPLEX AADvance 9100

  • 2. Part Number / 型号:9100 T9100@F2

  • 3. Architecture / 架构:TMR Triple Modular Redundancy, 3-2-0 fault tolerant

  • 4. Safety Level / 安全等级:SIL3

  • 5. Power Supply / 供电:Redundant 24VDC

  • 6. Communication / 通讯:Dual Ethernet, serial ports, Modbus support


Core Functions 核心功能

  • 1. 三重通道同步运算,硬件表决,单通道故障不中断安全控制,保障机组连续运行。
    Synchronous triple-channel operation and hardware voting, single channel fault will not interrupt safety control.

  • 2. 执行ESD紧急停车、F&G火气、BMS燃烧管理等高安全联锁逻辑。
    Execute ESD shutdown, F&G fire and gas, BMS burner management safety interlock logic.

  • 3. 冗余电源、双网口设计,配套I/O模块支持在线热插拔,不停机维护。
    Redundant power and dual Ethernet, hot-swap I/O modules for online maintenance without shutdown.

  • 4. 内置故障诊断、事件记录、SOE顺序事件,精准定位故障时间与原因。
    Built-in diagnostic, event log and SOE function for accurate fault time tracing.

  • 5. 标准机架插卡式,和AADvance全系列I/O卡件混合组态,灵活搭建SIS系统。
    Rack mount card, compatible with full AADvance I/O modules for flexible SIS configuration.


Application Scenarios 应用场景

  • 1. 石油、石化、天然气场站SIS安全仪表系统,紧急停车ESD控制柜。
    SIS ESD cabinets for oil, petrochemical and natural gas processing plants.

  • 2. 火电厂、联合循环电站锅炉、透平机组联锁保护,燃烧管理BMS。
    Boiler and turbine interlock protection, BMS for thermal and combined cycle power plants.

  • 3. 存量AADvance 9100系统故障处理器替换,恢复整套SIS安全功能。
    Spare replacement for failed processors to restore legacy AADvance SIS safety function.

  • 4. 化工罐区、压缩机房火气F&G检测报警与联锁切断系统。
    Fire & gas detection and interlock shutdown for chemical tank farms and compressor houses.

  • 5. 海外油气、化工成套SIS安全控制柜配套ICS TRIPLEX AADvance备件。
    AADvance spare parts for packaged SIS safety cabinets for overseas oil & gas projects.


FAQ 常见问答

Q:T9100@F2和T9100@F1版本区别?

A:主要为固件版本差异,F2是后续修订版本,修复部分诊断逻辑bug,组态软件版本需要匹配,不可直接混装。

Q:AADvance和Triconex TMR系统有什么不同?

A:AADvance是ICS Triplex新一代SIS平台,支持灵活混合TMR/2oo4架构;Triconex为传统TMR系统,硬件架构不同,卡件互不兼容。


Similar Models 相似型号

ICS TRIPLEX 9100 T9100@F1 AADvance Processor

ICS TRIPLEX T9400 AADvance Digital Input Module

ICS TRIPLEX T9451 AADvance Digital Output Module

TRICONEX 3008 TMR Processor Module

HIMA F8650X TMR Safety CPU

ICS TRIPLEX T9100@F3 Latest Revision


Tags: ICS TRIPLEX 9100 T9100@F2 TMR Safety Processor Module ICS TRIPLEX 9100 T9100@F2

Technical parameter
WhatsApp

WhatsApp

Business License

Business License

Main products

Main products

Wechat

Wechat

Leave Your Message

标签form报错:该表单下没有新增表单字段。
Leave a message
标签form报错:该表单下没有新增表单字段。