Products Description
Sieger 0574-A-012 0574-A-0131 Flame Detector Module
Sieger 0574-A-012搭配0574-A-0131组成紫外火焰检测总成,应用于燃烧管理BMS系统,依靠紫外传感技术识别火焰信号,区分真实火焰与炉壁高温辐射干扰。
Sieger 0574-A-012 matched with 0574-A-0131 is UV flame detector assembly for BMS. It uses UV sensing technology to identify flame and distinguish real flame from hot refractory radiation interference.


内置信号调理、自动自检回路,火焰有/无继电器触点输出给BMS主控,外壳坚固耐温防尘,适配炉膛侧恶劣工况,是电站锅炉、燃气轮机燃烧安全控制的常用备件。
It integrates signal conditioning and auto self-test circuit, relay contact output for flame on / flame off status. Rugged housing resists high temperature and dust, suitable for furnace side, widely used for boiler and gas turbine combustion safety control.

Main Specifications 技术参数
1. Product Series / 产品系列:Sieger UV Flame Detector Series
2. Part Numbers / 型号编码:0574-A-012,0574-A-0131
3. Function Type / 类型:Flame Detector Module 火焰检测模块
4. Key Features / 特性:UV flame sensing, anti-interference, built-in self-test, relay contact output, dust & heat resistant
5. Compatibility / 配套:BMS burner management system, boiler and gas turbine control system
Core Functions 核心功能
1. 紫外光谱火焰探测,过滤红外热辐射,规避炉壁高温造成误报。
UV spectrum flame detection, filter infrared thermal radiation to avoid false alarm from hot refractory.2. 实时火焰信号处理,火焰存在/熄火开关量输出至BMS系统。
Real-time flame signal processing, flame on / flame loss digital output to BMS controller.3. 周期性自检功能,探头故障、线路故障自动识别并报警。
Cyclic self-test function, automatically detect probe failure and wiring fault with alarm.4. 宽工况适应性,耐受炉膛附近高温、粉尘、震动环境。
Wide working condition adaptability, withstand high temperature, dust and vibration near furnace.5. 标准化安装接口,适配观火镜安装座,方便现场更换调试。
Standard mounting interface, fit sighting tube bracket for easy field replacement and commissioning.
Application Scenarios 应用场景
1. 火力发电厂锅炉BMS燃烧管理系统,单烧嘴火焰监测。
BMS burner management system of thermal power plant boiler, single burner flame monitoring.2. 燃气轮机、余热锅炉燃烧安全联锁保护回路。
Combustion safety interlock protection for gas turbine and HRSG.3. 石化加热炉、工业窑炉、燃气焚烧炉火焰安全监控。
Flame safety monitoring for petrochemical heater, industrial kiln and gas incinerator.4. 老旧BMS系统改造,火焰检测器老化失效备件替换。
Retrofit of old BMS system, replacement for aging flame detector units.5. 海外能源EPC项目燃烧安全仪表系统SIS备件备货。
SIS safety instrumented spare stocking for overseas energy EPC projects.
FAQ 常见问答
Q: 0574-A-012和0574-A-0131分开单独使用吗?
A: 二者一般成套组合使用,0574-A-012为探头主体,0574-A-0131为配套信号处理单元。
Q: 火焰频繁误报熄火优先检查哪里?
A: 优先检查观火镜片积灰、探头安装视角,再核对供电电压与信号接线。
Similar Models 相似型号
Sieger 0574-A-011
Sieger 0574-A-014
Honeywell 7010A
Fireye 95DSS2-1
DURAG D-LX 100
Tags: Sieger 0574-A-012 0574-A-0131 Flame Detector Module