MTL 8604-FT-FU Fused Field Terminal Module

MTL 8604-FT-FU is fused field terminal for MTL 8000 I/O system
Send Inquiry
Description
Argument
Products Description
MTL 8604-FT-FU | Fused Field Terminal Module

MTL 8604-FT-FU Fused Field Terminal Module


MTL 8604-FT-FU是MTL 8000 I/O系统配套带熔丝保护现场终端模块,8通道设计,专门搭配8103-AI-TX模拟量输入卡,为两线制4-20mA变送器提供回路供电与接线端子。

MTL 8604-FT-FU is fused field terminal for MTL 8000 I/O system. It has 8 channels and works with 8103-AI-TX analog input card, supplying power and termination for 2-wire 4-20mA transmitters.

MTL  8604-FT-FU (1).jpeg

每通道内置独立熔断器,回路短路、过流时单独熔断隔离故障,防止现场故障冲击背板与I/O卡件;标准DIN导轨卡装,紧凑布局适配控制柜,支持危险区域本安/非本安回路布线,是石化化工DCS柜常用备件。

Each channel is fitted with individual fuse to isolate short circuit and over-current fault, protecting I/O backplane and cards from field surge. Standard DIN rail mount for compact cabinet layout, compatible with hazardous area wiring for DCS systems in petrochemical plants.

MTL  8604-FT-FU (2).jpeg

MTL  8604-FT-FU (4).jpeg


Main Specifications 技术参数

  • 1. Product Series / 产品系列:MTL 8000 Distributed I/O System

  • 2. Part Numbers / 型号编码:8604-FT-FU

  • 3. Function Type / 类型:Fused Field Terminal Module 带熔丝现场终端模块

  • 4. Key Features / 特性:8 channels, per-channel fuse, 4-20mA loop power, DIN rail mount

  • 5. Compatibility / 配套:MTL 8103-AI-TX, MTL8000 backplane, 2-wire transmitters


Core Functions 核心功能

  • 1. 8通道现场信号端子转接,集中接入压力、温度两线制4-20mA变送器。
    8-channel field termination for 2-wire 4-20mA transmitters such as pressure and temperature sensors.

  • 2. 通道独立熔丝保护,单回路短路过流熔断隔离,故障不会蔓延至背板和I/O卡。
    Individual channel fuse protection, single loop fault isolated without damaging backplane and I/O card.

  • 3. 为现场仪表提供回路配电,简化柜内供电布线,配合AI卡完成信号采集。
    Provide loop power for field transmitters, simplify wiring and cooperate with AI card for signal acquisition.

  • 4. 标准DIN导轨安装,模块化排布,拆装更换便捷,方便机柜内扩容维护。
    DIN rail mounting, modular arrangement for quick installation, replacement and cabinet expansion.

  • 5. 适配防爆危险区布线规范,满足石化、油气现场仪表回路安全接线要求。
    Designed for hazardous area wiring, comply with safety requirements of petrochemical and oil & gas sites.


Application Scenarios 应用场景

  • 1. MTL8000 DCS控制柜端子备件替换,化工装置、油气处理厂控制系统维护库存。
    Replacement spare for MTL8000 DCS cabinets, maintenance stock for chemical and oil & gas facilities.

  • 2. 两线制模拟量变送器回路接线,压力、液位、温度仪表信号集中转接保护。
    Field wiring for 2-wire analog transmitters, termination and protection for pressure, level and temperature signals.

  • 3. 海外EPC项目成套备件打包,搭配8103-AI-TX卡件、背板整套供货交付。
    Complete spare package with 8103-AI-TX card and backplane for overseas EPC automation projects.

  • 4. 存量MTL8000系统改造扩容,新增模拟测点,增加带熔丝安全端子单元。
    Retrofit and expansion of legacy MTL8000 systems, add analog measurement points with fused terminals.

  • 5. 海上平台、炼油厂自控系统,危险区域仪表回路限流保护,降低故障停机风险。
    Automation system for offshore platforms and refineries, limit current for hazardous area instrument loops.


FAQ 常见问答

Q: 8604-FT-FU和8602-FT-ST主要区别是什么?

A: 8604-FT-FU带独立熔丝保护;8602-FT-ST是标准无熔丝版本,适合无短路保护要求的回路。

Q: 它可以直接搭配MTL其他系列安全栅使用吗?

A: 它属于MTL8000 I/O配套端子单元,优先配套8103卡件,不建议和独立安全栅混用。


Similar Models 相似型号

8602-FT-ST

8603-FT-FU

8605-FT-TC

MTL 8103-AI-TX

8611-FT-FU


Tags: MTL 8604-FT-FU Fused Field Terminal Module MTL 8604-FT-FU

Technical parameter
WhatsApp

WhatsApp

Business License

Business License

Main products

Main products

Wechat

Wechat

Leave Your Message

标签form报错:该表单下没有新增表单字段。
Leave a message
标签form报错:该表单下没有新增表单字段。