QQ

电话

15685359870

WhatsApp

+86 15685359870

Yokogawa 16407‑1‑1 Safety I/O Terminal Unit

Yokogawa 16407‑1‑1 Safety I/O Terminal UnitThe Yokogawa 16407‑1‑1 is safety‑cert
Send Inquiry
Description
Argument
Products Description

Yokogawa 16407‑1‑1 Safety I/O Terminal Unit


The Yokogawa 16407‑1‑1 is safety‑certified terminal hardware for ProSafe‑PLC SIS safety instrumented systems. It serves as intermediate signal interface between safety I/O modules and field‑side instruments, offering screw‑lock terminals for safety‑loop sensors, position switches and field actuators.


image.png


This compact modular terminal unit integrates surge suppression and EMI filtering circuits to suppress transient noise from field wiring loops. It supports convenient on‑site maintenance without re‑terminating external field cables, and is designed for cabinet‑internal installation in petrochemical, refinery and power‑plant SIS safety cabinets.


Main Specifications

  • Brand: Yokogawa; Model: 16407‑1‑1; Type: SIS Safety I/O Terminal Unit
  • Applicable System: Yokogawa ProSafe‑PLC Safety Instrumented System
  • Core Tasks: Field wiring transition, surge over‑voltage protection, EMI noise filtering, on‑site loop test access
  • Signal Interface: Screw‑type field wiring terminals, internal mating connector for ProSafe‑PLC I/O modules
  • Installation: Mounted on ProSafe‑PLC rack chassis, matched with corresponding safety I/O modules
  • Protection: Built‑in transient‑voltage suppression and signal filtering for field instrument loops
  • Operating Environment: 0℃ ~ +55℃, 5%‑95% RH non‑condensing, industrial anti‑vibration grade
  • Mechanical: Compact modular cabinet‑mount unit, IP20 protection rating
  • Certifications: CE, TÜV certified for IEC61508 SIL‑3 safety‑related application scenarios

Core Functions

  • Provide stable screw‑lock terminal points to connect field‑device cables and bridge field wiring to ProSafe‑PLC safety I/O modules.
  • Integrate surge‑suppression and filter components to restrain transient voltage spikes and electromagnetic interference from complex field environments.
  • Allow terminal unit replacement without disconnecting external field cables, reducing system downtime during cabinet maintenance work.
  • Realize physical isolation between field wiring side and safety logic circuits to limit fault propagation across safety‑critical control loops.
  • Offer accessible test points for loop inspection, commissioning and on‑site fault diagnosis of SIS instrument control circuits.
  • Rugged industrial‑grade modular structure supports long‑term continuous running in safety‑related industrial control cabinet environments.

Application Scenarios

  • Spare‑part replacement for Yokogawa ProSafe‑PLC SIS safety cabinets in petrochemical plants, refineries and power‑generation facilities.
  • Field‑wiring transition hardware for ESD emergency shutdown and burner‑management safety instrumented control loops.
  • Maintenance backup inventory for renovation and after‑sales maintenance projects of legacy Yokogawa safety‑PLC equipment.
  • Matching terminal unit cooperating with ProSafe‑PLC I/O modules, rack chassis and safety‑control HMI panel.
  • Retrofit replacement for aged terminal units with terminal burnout, poor contact and signal‑loop interference faults.
  • Global aftermarket spare supply for automation maintenance teams maintaining Yokogawa safety‑control equipment worldwide.


f42bece118407243826cf3d10e328deb.png


Tags: Yokogawa 16407‑1‑1 Safety I/O Terminal Unit Yokogawa 16407‑1‑1

Technical parameter
WhatsApp

WhatsApp

Business License

Business License

Main products

Main products

Wechat

Wechat

Leave Your Message

标签form报错:该表单下没有新增表单属性。
Leave a message
标签form报错:该表单下没有新增表单属性。