Yokogawa 16147‑51‑2 Safety I/O Terminal Unit

Yokogawa 16147‑51‑2 Safety I/O Terminal UnitThe Yokogawa 16147‑51‑2 is a safety‑
Send Inquiry
Description
Argument
Products Description

Yokogawa 16147‑51‑2 Safety I/O Terminal Unit


The Yokogawa 16147‑51‑2 is a safety‑grade terminal unit for Yokogawa ProSafe‑PLC SIS safety instrumented systems. It acts as the physical signal interface between safety I/O modules and field instruments, providing screw‑lock terminals for safety‑loop field sensors, position switches and actuators.


image.png


This modular terminal assembly integrates built‑in surge suppression and EMI filtering circuits to absorb transient interference from field instrument loops. It supports convenient hot‑swap maintenance without re‑terminating external field cables, and is designed for cabinet‑internal installation for petrochemical, refinery and power‑plant SIS safety systems.


Main Specifications

  • Brand: Yokogawa; Model: 16147‑51‑2; Type: SIS Safety I/O Terminal Unit
  • Applicable System: Yokogawa ProSafe‑PLC Safety Instrumented System
  • Core Tasks: Field wiring transition, surge protection, noise filtering, on‑site commissioning and test access
  • Signal Interface: Screw‑type field wiring terminals, internal mating connector for ProSafe‑PLC I/O modules
  • Installation: Mounted on ProSafe‑PLC rack chassis, matched with corresponding safety I/O modules
  • Protection: Integrated transient‑voltage suppression and EMI signal filtering for field control loops
  • Operating Environment: 0℃ ~ +55℃, 5%‑95% RH non‑condensing, industrial anti‑vibration grade
  • Mechanical: Compact modular cabinet‑mount unit, IP20 protection rating
  • Certifications: CE, TÜV certified for IEC61508 SIL‑3 safety‑related application

Core Functions

  • Provide reliable screw‑lock terminal points to connect field‑device cables and bridge field wiring to ProSafe‑PLC safety I/O modules.
  • Built‑in surge‑suppression and filter components to restrain transient voltage spikes and electromagnetic noise from field environments.
  • Allow terminal unit replacement without disconnecting external field cables, minimizing system downtime during cabinet maintenance.
  • Implement physical separation between field wiring side and safety logic circuits to restrict fault propagation across safety‑critical loops.
  • Offer accessible test points for loop inspection, commissioning and troubleshooting of SIS instrument control circuits.
  • Industrial‑hardened modular structure supports long‑term continuous running in safety‑related industrial control cabinet environments.

Application Scenarios

  • Spare‑part replacement for Yokogawa ProSafe‑PLC SIS safety cabinets in petrochemical plants, refineries and power‑generation facilities.
  • Field‑wiring transition hardware for ESD emergency shutdown and burner‑management safety instrumented control loops.
  • Maintenance backup inventory for renovation and after‑sales maintenance projects of legacy Yokogawa safety‑PLC equipment.
  • Matching terminal unit cooperating with ProSafe‑PLC I/O modules, rack chassis and safety‑control HMI panel.
  • Retrofit replacement for aged terminal units with terminal burnout, poor contact and signal‑loop interference faults.
  • Global aftermarket spare supply for automation maintenance teams maintaining Yokogawa safety‑control equipment worldwide.


f42bece118407243826cf3d10e328deb.png


Tags: Yokogawa 16147‑51‑2 Safety I/O Terminal Unit Yokogawa 16147‑51‑2

Technical parameter
WhatsApp

WhatsApp

Business License

Business License

Main products

Main products

Wechat

Wechat

Leave Your Message

标签form报错:该表单下没有新增表单属性。
Leave a message
标签form报错:该表单下没有新增表单属性。