Yokogawa 16137‑119 Terminal Adapter Module

Yokogawa 16137‑119 Terminal Adapter ModuleThe Yokogawa 16137‑119 is a field term
Send Inquiry
Description
Argument
Products Description

Yokogawa 16137‑119 Terminal Adapter Module


The Yokogawa 16137‑119 is a field terminal adapter module for ProSafe‑PLC SIS safety instrumented systems. It serves as intermediate signal interface between safety I/O modules and field wiring, providing reliable screw‑type terminal connections for process‑industry field sensors and actuators.


image.png


This plug‑in terminal unit adopts industrial‑grade wiring terminals and internal signal conditioning circuits. It supports convenient field wiring modification and troubleshooting, and can be replaced without modifying external field cables. It is widely deployed inside petrochemical, refinery and power‑plant SIS safety cabinets.


Main Specifications

  • Brand: Yokogawa; Model: 16137‑119; Type: SIS I/O Terminal Adapter Module
  • Applicable System: Yokogawa ProSafe‑PLC Safety Instrumented System
  • Core Tasks: Field signal terminal conversion, wiring transition, signal filtering, convenient on‑site maintenance interface
  • Signal Interface: Screw‑type field wiring terminals, internal back‑plane connector for mating I/O module
  • Installation: Installed on ProSafe‑PLC module rack, matched with corresponding I/O hardware
  • Isolation: Built‑in signal filtering and surge suppression for field circuit protection
  • Operating Environment: 0℃ ~ +55℃, 5%‑95% RH non‑condensing, industrial anti‑vibration grade
  • Mechanical: Compact modular structure, IP20 protection grade for cabinet‑internal installation
  • Certifications: CE, TÜV certified for IEC61508 SIL‑3 safety‑related application scenarios

Core Functions

  • Provide screw‑lock terminal points for field‑device cables, realizing safe transition between field wiring and SIS I/O modules.
  • Integrate signal filtering and surge‑suppression components to restrain interference and transient voltage from field instrument loops.
  • Allow independent disassembly and replacement without re‑terminating external field cables, greatly simplifying cabinet maintenance work.
  • Physically separate field wiring side from safety‑logic module side, reducing fault spread risk for safety‑related control loops.
  • Support quick circuit inspection and signal testing via terminal points during commissioning and on‑site troubleshooting procedures.
  • Industrial‑grade modular hardware design adapts to long‑term continuous operation inside safety‑instrumented control cabinets.

Application Scenarios

  • Spare‑part replacement for Yokogawa ProSafe‑PLC SIS safety cabinets in petrochemical plants, refineries and power‑generation sites.
  • Field‑wiring transition component for ESD emergency shutdown and burner‑management safety instrumented control loops.
  • Maintenance backup inventory for renovation and after‑sales maintenance projects of legacy Yokogawa safety‑PLC equipment.
  • Matching terminal adapter cooperating with ProSafe‑PLC I/O modules, system chassis and safety‑control HMI panel.
  • Retrofit replacement for old terminal units with terminal burnout, poor contact and signal‑loop interference faults.
  • Global aftermarket spare supply for automation maintenance teams maintaining Yokogawa safety‑control equipment worldwide.