QQ

电话

15685359870

WhatsApp

+86 15685359870

Yokogawa 16114‑500 / 16114‑5006 Modulack Module Card Rack

Yokogawa 16114‑500 / 16114‑5006 Modulack Module Card RackThe Yokogawa 16114‑500
Send Inquiry
Description
Argument
Products Description

Yokogawa 16114‑500 / 16114‑5006 Modulack Module Card Rack


The Yokogawa 16114‑500 and 16114‑5006 form a complete Modulack rack assembly for Yokogawa ProSafe‑PLC safety instrumented systems. The 16114‑500 is the main mechanical chassis, while 16114‑5006 serves as the integrated backplane bus unit, providing slot positions, power distribution and high‑speed backplane communication for safety CPU and I/O modules.


image.png

image.png


This rack assembly supports hot‑swap insertion of safety modules and provides 24 VDC bus power for each slot. It meets functional‑safety mechanical requirements, with reinforced shielding against EMI interference. Designed for 19‑inch cabinet mounting, it runs continuously in petrochemical, refinery and power‑plant SIS safety cabinets.


Main Specifications

  • Brand: Yokogawa; Model: 16114‑500 (Chassis), 16114‑5006 (Backplane); Type: ProSafe‑PLC Module Card Rack Assembly
  • Applicable System: Yokogawa ProSafe‑PLC SIS safety instrumented control system
  • Core Tasks: Module mechanical housing, backplane high‑speed data bus, 24 VDC power distribution, EMI shielding, hot‑swap support
  • Signal Interface: Internal backplane bus connectors, DC power bus terminals for 24 VDC input
  • Installation: Standard 19‑inch cabinet rack‑mount structure
  • Power Bus: 24 VDC field auxiliary power distributed to each module slot
  • Operating Environment: 0℃ ~ +55℃, 5%‑95% RH non‑condensing, industrial anti‑vibration grade
  • Mechanical: Robust metal chassis, conformal‑coated backplane circuit board, IP20 protection grade
  • Certifications: CE, TÜV certified for IEC61508 SIL‑3 safety‑related system deployment

Core Functions

  • Provide standardized slot positions for ProSafe‑PLC safety CPU, digital and analog I/O modules.
  • Integrate high‑speed backplane data bus to realize high‑reliability data exchange between all rack‑mounted modules.
  • Distribute stabilized 24 VDC bus power to each inserted safety module through the 16114‑5006 backplane unit.
  • Support hot‑swap replacement of individual I/O and communication modules without shutting down the whole SIS safety system.
  • Built‑in EMI/RFI shielding structure to suppress electromagnetic interference from heavy‑duty industrial field environment.
  • Industrial‑hardened mechanical structure adapts to long‑term continuous running within safety‑related control cabinets.

Application Scenarios

  • Spare‑part replacement for Yokogawa ProSafe‑PLC SIS safety cabinets in refineries, petrochemical plants and power‑generation sites.
  • Core mechanical and bus infrastructure for ESD emergency shutdown and burner management safety instrumented systems.
  • Maintenance backup inventory for renovation and after‑sales maintenance projects of legacy Yokogawa safety‑PLC equipment.
  • Matching rack assembly cooperating with ProSafe‑PLC CPU unit, safety I/O modules and system HMI operation panel.
  • Retrofit replacement for old rack assemblies with backplane bus damage and power‑distribution failure faults.
  • Global aftermarket spare supply for automation maintenance teams maintaining Yokogawa safety‑control equipment worldwide.

f42bece118407243826cf3d10e328deb.png


Tags: Yokogawa 16114‑500 16114‑5006 Modulack Module Card Rack

Technical parameter
WhatsApp

WhatsApp

Business License

Business License

Main products

Main products

Wechat

Wechat

Leave Your Message

标签form报错:该表单下没有新增表单属性。
Leave a message
标签form报错:该表单下没有新增表单属性。