欢迎浏览朗思自控科技有限公司官方网站!!
Industry Information
GE 362A1052P004 RS‑FS‑9001 UV Flame Detector
联系人:李经理
电话:15685359870
手机:15685359870
QQ:3165088973
邮箱:3165088973@qq.com
地址: 中国

 
产品详情


GE 362A1052P004 RS‑FS‑9001 UV Flame Detector


GE 362A1052P004 RS‑FS‑9001 is a Reuter‑Stokes ultraviolet flame detector for gas turbine and boiler combustion monitoring systems. Adopting silicon‑carbide UV photodiode sensing technology, it captures ultraviolet spectral signal from flame combustion, converts flame status into standard 4‑20 mA analog output for turbine protection and burner safety‑interlock logic.


This stainless‑steel housed detector supports hazardous‑area installation with ATEX / IECEx certification. It features fast response time and strong anti‑interference capability against ambient light disturbance, widely used as replacement spare‑part for on‑site troubleshooting, combustion‑system maintenance and retrofit projects.


Main Specifications

  • Brand: GE Reuter‑Stokes
  • Model: 362A1052P004, Type: RS‑FS‑9001
  • Product Type: Ultraviolet UV Flame Detector Sensor
  • Detection Principle: Silicon‑carbide UV photodiode
  • Output Signal: 4‑20 mA current loop
  • Power Supply: 24VDC ±10%
  • Response Time: Less than 50 ms typical
  • Process Interface: 3/4‑inch NPT thread mounting
  • Certification: ATEX, IECEx, Class I Div 2 hazardous‑area approval
  • Operating Temperature:‑40℃ ~ +85℃
  • Protection Grade: IP66 stainless‑steel enclosure
  • Application: Spare‑part replacement for gas‑turbine & boiler flame‑monitoring equipment

Core Functions

  • Detect UV spectral radiation generated by fuel‑gas or fuel‑oil flame combustion
  • Convert flame presence / loss status into 4‑20 mA analog signal sent to turbine control system
  • Strong anti‑interference performance reduces false alarm caused by ambient light and hot‑metal radiation
  • Fast response supports quick flame‑loss trip protection for burner and gas‑turbine unit
  • Explosion‑proof hardware design adapts to hazardous zone installation of power‑plant and petrochemical site
  • Stainless‑steel housing provides good corrosion‑resistance for long‑term furnace‑side working environment
  • NPT threaded interface simplifies field installation, optical‑path alignment and spare‑part replacement operation

Application Scenarios

  • Thermal‑power‑plant gas‑turbine and boiler flame‑monitoring cabinet configuration projects
  • Petrochemical‑industry heating‑furnace and burner safety‑combustion‑monitoring supporting projects
  • On‑site flame‑detector fault replacement and combustion‑protection‑system daily maintenance work
  • Legacy turbine‑combustion‑monitoring‑system renovation for upgrading flame‑detection reliability
  • Legacy GE Reuter‑Stokes flame‑sensor spare‑parts replacement scenarios
  • Spare‑parts inventory backup for power‑plant turbine‑control‑room cabinets
  • Furnace and gas‑turbine flame‑monitoring‑hardware maintenance supporting engineering projects